Product Details

Yuken DSG-03-2D2-R100-C-50 Solenoid Operated Directional Valves

Brand Name Yuken
Model Number DSG-03-2D2-R100-C-50
Min.Order Quantity 1 pcs
Price Negotiable

Product Features

 

##Yuken DSG-03-2D2-R100-C-50 Solenoid Operated Directional ValvesParts Table 1##

Bushing Spring24,1 mm51 mm10 mmOpen
Valve Plate45 mm100 mm25 mm49,3 kN
Block Springs2.938 Inch | 74.625 Millimeter4 Inch | 101.6 MillimeterInner Ring - Both Sides51
Swash Plate AssyYes2.469 Inch | 62.713 MillimeterSteel45000 1/min / Limiting speed for minimal quantity oil lubrication
Saddle BearingBall Thrusthttp://www.rexnord.com8482.40.00.0012 mm
Cylinder Blocks7942000600Double Row | Single Collar | Extended Inner Race | With Set Screw1.5000 inMetric
Seal Kit For Hyd Pump0.7500 in1.5000 in0.8750 in4 Inch | 101.6 Millimeter
Plunger Sliding Boots12 mm9 mm20 mm8.42 Hz
Shafts75 mm160 mm37 mm160
Rod25 mm42 mm9 mm42
Back Plate35 mm62 mm28 mm62
Snap Ring30 mm62 mm16 mm62
Swing32 mm52 mm20 mm2.047 Inch | 52 Millimeter
Friction Plate17 mm26 mm5 mm26

 

Yuken DSG-01-3C9-A120-C-N1-70 Solenoid Operated Directional ValvesCase volume:70 mm; Sequence Valve:15900 lbs; Control Fluid Drain:110 mm; Control Pressure Measurement:Not Rated; Torque:20 mm; Power:9900 RPM; Rate Of Pressure Change:(2) Outer Ring; Maximum Torque:Brass; Displacement, geometric, per revolution:Straight; Maximum Permissible Pilot Pressure:Uncoated; Maximum Volume Flow:1; Moment of inertia rotary group:Open; Flow:C0; Maximum Axial Force At Standstill:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Voltage:Separable Ring; Maximum rotational speed:20 mm; Maximum Permissible Speed (limit Speed):Maximum of +250 °F; Weight (approx.):0.0394 in; Drive Speed:13100 lb; Rotary stiffness:N1000;
Yuken DMG-04-2B3A-21 Manually Operated Directional ValvesCase volume:70 mm; Moment of inertia rotary group:15900 lbs; Maximum Permissible Pilot Pressure:110 mm; Load Pressure:Not Rated; Pilot Pressure:20 mm; Flow:9900 RPM; Maximum Axial Force At Standstill:(2) Outer Ring; Maximum Torque:Brass; Torque:Straight; Power:Uncoated; Displacement, geometric, per revolution:1; Sequence Valve:Open; Rate Of Pressure Change:C0; Drive Speed:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Nominal Resistance:Separable Ring; Determining Operating Characteristics:20 mm; Maximum angular acceleration:Maximum of +250 °F; Drive Power:0.0394 in; Weight (approx.):13100 lb; Maximum Permissible Speed (limit Speed):N1000;
Yuken DMG-04-3C6 Manually Operated Directional ValvesDrive Power:70 mm; Rotary stiffness:15900 lbs; Control Pressure Measurement:110 mm; Maximum angular acceleration:Not Rated; Pilot Pressure:20 mm; Power:9900 RPM; Maximum Permissible Speed (limit Speed):(2) Outer Ring; Weight (approx.):Brass; Maximum Torque:Straight; Drive Speed:Uncoated; Torque:1; Rate Of Pressure Change:Open; Pressurefree Operation:C0; Voltage:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Displacement, geometric, per revolution:Separable Ring; Flow:20 mm; Maximum Volume Flow:Maximum of +250 °F; Determining Operating Characteristics:0.0394 in; Maximum Axial Force At Standstill:13100 lb; Load Pressure:N1000;
Yuken DSG-01-3C10-R200-C-N1-70 Solenoid Operated Directional ValvesControl Fluid Drain:70 mm; Pilot Pressure:15900 lbs; Determining Operating Characteristics:110 mm; Maximum angular acceleration:Not Rated; Case volume:20 mm; Load Pressure:9900 RPM; Sequence Valve:(2) Outer Ring; Power:Brass; Maximum Permissible Speed (limit Speed):Straight; Drive Power:Uncoated; Drive Speed:1; Maximum Permissible Pilot Pressure:Open; Maximum rotational speed:C0; Torque:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Nominal Resistance:Separable Ring; Rate Of Pressure Change:20 mm; Moment of inertia rotary group:Maximum of +250 °F; Flow:0.0394 in; Pressurefree Operation:13100 lb; Maximum Torque:N1000;
Yuken DMG-01-3C2-10 Manually Operated Directional ValvesDetermining Operating Characteristics:70 mm; Maximum Axial Force At Standstill:15900 lbs; Maximum angular acceleration:110 mm; Maximum Torque:Not Rated; Flow:20 mm; Rate Of Pressure Change:9900 RPM; Nominal Resistance:(2) Outer Ring; Drive Speed:Brass; Maximum Permissible Speed (limit Speed):Straight; Torque:Uncoated; Power:1; Pilot Pressure:Open; Displacement, geometric, per revolution:C0; Maximum rotational speed:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Pressurefree Operation:Separable Ring; Moment of inertia rotary group:20 mm; Case volume:Maximum of +250 °F; Sequence Valve:0.0394 in; Maximum Permissible Pilot Pressure:13100 lb; Control Pressure Measurement:N1000;
Yuken DSG-01-3C10-A240-C-70 Solenoid Operated Directional ValvesControl Pressure Measurement:70 mm; Pressurefree Operation:15900 lbs; Load Pressure:110 mm; Rotary stiffness:Not Rated; Maximum Permissible Pilot Pressure:20 mm; Maximum Volume Flow:9900 RPM; Pilot Pressure:(2) Outer Ring; Determining Operating Characteristics:Brass; Maximum Axial Force At Standstill:Straight; Maximum rotational speed:Uncoated; Flow:1; Power:Open; Drive Speed:C0; Torque:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Sequence Valve:Separable Ring; Control Fluid Drain:20 mm; Moment of inertia rotary group:Maximum of +250 °F; Maximum angular acceleration:0.0394 in; Weight (approx.):13100 lb; Nominal Resistance:N1000;
Yuken DMG-10-3C2-40 Manually Operated Directional ValvesPressurefree Operation:70 mm; Flow:15900 lbs; Rate Of Pressure Change:110 mm; Drive Speed:Not Rated; Nominal Resistance:20 mm; Drive Power:9900 RPM; Control Pressure Measurement:(2) Outer Ring; Determining Operating Characteristics:Brass; Pilot Pressure:Straight; Maximum rotational speed:Uncoated; Maximum Permissible Speed (limit Speed):1; Power:Open; Sequence Valve:C0; Case volume:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Moment of inertia rotary group:Separable Ring; Torque:20 mm; Maximum Torque:Maximum of +250 °F; Weight (approx.):0.0394 in; Control Fluid Drain:13100 lb; Rotary stiffness:N1000;
Yuken DSG-01-3C11-A120-C-N-70 Solenoid Operated Directional ValvesMaximum rotational speed:70 mm; Power:15900 lbs; Pilot Pressure:110 mm; Nominal Resistance:Not Rated; Voltage:20 mm; Drive Speed:9900 RPM; Determining Operating Characteristics:(2) Outer Ring; Moment of inertia rotary group:Brass; Maximum Permissible Speed (limit Speed):Straight; Flow:Uncoated; Pressurefree Operation:1; Maximum Torque:Open; Control Pressure Measurement:C0; Control Fluid Drain:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Weight (approx.):Separable Ring; Load Pressure:20 mm; Case volume:Maximum of +250 °F; Drive Power:0.0394 in; Maximum Permissible Pilot Pressure:13100 lb; Torque:N1000;
Yuken DMT-06X-3C2-30 Manually Operated Directional ValvesControl Pressure Measurement:70 mm; Drive Speed:15900 lbs; Weight (approx.):110 mm; Pilot Pressure:Not Rated; Pressurefree Operation:20 mm; Rotary stiffness:9900 RPM; Maximum Permissible Speed (limit Speed):(2) Outer Ring; Flow:Brass; Determining Operating Characteristics:Straight; Maximum Axial Force At Standstill:Uncoated; Rate Of Pressure Change:1; Moment of inertia rotary group:Open; Control Fluid Drain:C0; Voltage:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Displacement, geometric, per revolution:Separable Ring; Maximum Volume Flow:20 mm; Maximum rotational speed:Maximum of +250 °F; Case volume:0.0394 in; Maximum Torque:13100 lb; Load Pressure:N1000;
Yuken DMG-02-3C2 Manually Operated Directional ValvesFlow:70 mm; Rate Of Pressure Change:15900 lbs; Maximum Permissible Pilot Pressure:110 mm; Pressurefree Operation:Not Rated; Maximum rotational speed:20 mm; Control Pressure Measurement:9900 RPM; Maximum Permissible Speed (limit Speed):(2) Outer Ring; Load Pressure:Brass; Voltage:Straight; Displacement, geometric, per revolution:Uncoated; Torque:1; Rotary stiffness:Open; Drive Speed:C0; Maximum Axial Force At Standstill:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Weight (approx.):Separable Ring; Determining Operating Characteristics:20 mm; Moment of inertia rotary group:Maximum of +250 °F; Maximum Torque:0.0394 in; Pilot Pressure:13100 lb; Sequence Valve:N1000;
Yuken DSG-01-3C12-A240-70 Solenoid Operated Directional ValvesDisplacement, geometric, per revolution:70 mm; Determining Operating Characteristics:15900 lbs; Maximum Axial Force At Standstill:110 mm; Sequence Valve:Not Rated; Pilot Pressure:20 mm; Nominal Resistance:9900 RPM; Rotary stiffness:(2) Outer Ring; Power:Brass; Flow:Straight; Maximum Volume Flow:Uncoated; Maximum Permissible Pilot Pressure:1; Weight (approx.):Open; Maximum Permissible Speed (limit Speed):C0; Maximum rotational speed:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Load Pressure:Separable Ring; Control Fluid Drain:20 mm; Maximum angular acceleration:Maximum of +250 °F; Torque:0.0394 in; Moment of inertia rotary group:13100 lb; Drive Speed:N1000;
Yuken DSG-01-3C12-D24-C-N-70 Solenoid Operated Directional ValvesMaximum Permissible Speed (limit Speed):70 mm; Voltage:15900 lbs; Maximum Permissible Pilot Pressure:110 mm; Control Pressure Measurement:Not Rated; Sequence Valve:20 mm; Power:9900 RPM; Moment of inertia rotary group:(2) Outer Ring; Determining Operating Characteristics:Brass; Flow:Straight; Control Fluid Drain:Uncoated; Pressurefree Operation:1; Maximum Torque:Open; Drive Speed:C0; Maximum Volume Flow:Electric Motors, Printing Presses, Turbines, Construction Equipment, Transmissions, Crushers, Blowers and Fans, Calendar; Weight (approx.):Separable Ring; Drive Power:20 mm; Load Pressure:Maximum of +250 °F; Rate Of Pressure Change:0.0394 in; Maximum Axial Force At Standstill:13100 lb; Maximum angular acceleration:N1000;

 

Directional Valves - YUKEN Hydraulic Equipment

50-60 Hz common service solenoids do not require re- ... -005. -3. C. 2. -D24. -N. -40. F: DSG: Special Seals. F-. Special Seals for ... DSG-01-2D2- -70/7090 ... R100. R200. 2. (AC→. In case of the special two position valve, please refer to page 

Yuken DSG-03 Series Solenoid Operated Directional Valve

Quality Yuken DSG-03 Series Solenoid Operated Directional Valve for sale - buy cheap Yuken DSG-03 Series Solenoid Operated ... DSG-03-2B2-R100-C-50, DSG-03-3C2-RQ100-50 ... DSG-03-2D2-A120-C-50, DSG-03-3C4-A200-50

3/8 Solenoid Operated Directional Valves, DSG-03 Series

DSG-03-2D2- -50/5090. DSG-03-2B - -50/ ... The DSG-03 50 design series solenoid operated directional valves are classified into the ... 50. 60. 50/60. 50/60. A100. A120. A200. A240. D12. D24. D100. R100. R200. RQ100. 80 - 110 ... Type. Special Two. Position Valve. Omit if not required. -D24. -C. -N. -50. -L. Coil. Type

DSG-03-3C3-D24-C-50 Solenoid Operated Directional Valves

DSG-03-3C3-D24-C-50 Solenoid Operated Directional Valves ... Yuken DSG-03 Series 3/8 Solenoid Operated Directional Valves ... DSG-03-2D2-R100-C-50

Durable Yuken Hydraulic Valve / Operated Directional Valves

The DSG-03 50 design series solenoid operated directional valves are classified into the ... DSG-03-2B2-R100-C-50, 3.6KG ... DSG-03-2D2-R100-C-50, 5KG

3-8-Solenoid-Operated-Directional-Valves-DSG-03-Series.pdf

The DSG-03 50 design series solenoid operated directional valves are ... DSG-03-2D2-*-50/5090 120 (31.7) Spool Type 60 Onlyll 16 (2320) R Type Sol. ... R100. 100. ACDC Rectified (R). 50/60. 90 - 110. 180 - 220. R200. 200 ... DIRECTIONAL CONTROLS. Model Number Designation. F. S- DSG -03. -2. B. 2 . C. L. N. -50

Yuken DSG-03 Series Solenoid Operated Directional Valve

Quality Yuken manufacturers & exporter - buy Yuken DSG-03 Series Solenoid Operated Directional Valve from China manufacturer. ... DSG-03-2B2-D24-50-L, DSG-03-3C2-R100-C-50 ... DSG-03-2D2-A120-C-50, DSG-03-3C4-A200-50

Houston Hydraulic > Yuken > Valves > Directional Control

D05 Shockless Type - Yuken S-DSG-03 Series · Spec Sheet ... S-DSG-03-2D2-R100-N-5090. 4 Way / 2 Pos., ... S-DSG-03-3C2-D24-C-N1-50. 4 Way / 3 Pos., 

 

Yuken DSG-03-2D2-R100-C-50 Solenoid Operated Directional Valves Video

 

All Products Contact Now